Issue Details (XML | Word | Printable)

Key: PCC-317
Type: Bug Bug
Status: Resolved Resolved
Resolution: Fixed
Priority: Minor Minor
Assignee: Anders Magnusson
Reporter: Fred J. Tydeman
Votes: 0
Watchers: 0
Operations

If you were logged in you would be able to see more operations.
pcc

FLT_EVAL_METHOD not defined

Created: 14/Apr/11 05:15 PM   Updated: 03/May/14 12:40 PM
Component/s: None
Affects Version/s: None
Fix Version/s: None

Environment: Intel Core i5 (64 bit); Linux Fedora Core 14 (64 bit); pcc of 2011/02/21


 Description  « Hide
The macro symbol FLT_EVAL_METHOD of <float.h> is not defined.
On Intel x86 computers, there are two floating-point units (FPUs).
For a x87 FPU, FLT_EVAL_METHOD should be 2
For a SSE FPU, FLT_EVAL_METHOD should be 0
This is supposed to affect how floating-point expressions for static initializers are evaluated.


 All   Comments   Change History      Sort Order: Ascending order - Click to sort in descending order
Anders Magnusson made changes - 03/May/14 12:40 PM
Field Original Value New Value
Assignee Anders Magnusson [ ragge ]
Anders Magnusson made changes - 03/May/14 12:40 PM
Status Open [ 1 ] Resolved [ 5 ]
Resolution Fixed [ 1 ]